CD3 Series

Optex FA
Sensor de imagen CMOS para medir el desplazamiento de alta precisión. Ajuste de span y funciones de compensación para un control flexible de la salida analógica. Alarma preestablecida de pico / límite inferior del valor analógico. La detección precisa de los objetivos de colores oscuros.

Especificaciones





Model Cable type 2control output CD33-30N / P CD33-50N / P CD33-85N / P CD33-120N / P CD33-250N / P
2control output
+ Analog 4-20mA
CCD33-30NA / PA CD33-50NA / PA CD33-85NA / PA CD33-120NA / PA CD33-250NA / PA
2control output
+ Analog 0-10V
CD33-30NV / PV CD33-50NV / PV CD33-85NV / PV CD33-120NV / PV CD33-250NV / PV
1control output
+ RS422
CD33-30N-422
CD33-30P-422V
CD33-50N-4222
CD33-50P-422
CD33-85N-422
CD33-85P-422
CD33-120N-422
CD33-120P-422
CD33-250N-422
CD33-250P-422
Connector type 2control output CD33-30CN / CP CD33-50CN / CP CD33-85CN / CP CD33-120CN / CP CD33-250CN / CP
2control output
+ Analog 4-20mA
CD33-30CNA / CPA CD33-50CNA / CPA CD33-85CNA / CPA CD33-120CNA / CPA CD33-250CNA / CPA
2control output
+ Analog 0-10V
CD33-30CNV / CPV CD33-50CNV / CPV CD33-85CNV / CPV CD33-120CNV / CPV CD33-250CNV / CPV
1control output
+ RS422
CD33-30CN-422
CD33-30CP-422
CD33-50CN-422
CD33-50CP-422
CD33-85CN-422
CD33-85CP-422
CD33-120CN-422
CD33-120CP-422
CD33-250CN-422
CD33-250CP-422
Control output N = NPN output, P = PNP output
Measurement range 30±4mm 50±10mm 85±20mm 120±60mm 250±150mm
Full scale 8mm 20mm 40mm 120mm 300mm
Light source Red laser diode (wave length 655nm)
Peak power 1mW max.
IEC/JIS Class Class 2
FDA CLASS CLASS ?
Spot size (approx.volume) (*1) Near 0.15×0.15mm 0.6×1.2mm 0.9×1.5mm 1.2×1.8mm 1.5×2.5mm
Middle 0.1×0.1mm 0.5×1.0mmm 0.75×1.25mm 1.0×1.5mm 1.75×3.5mm
Far 0.15×0.15mm 0.4×0.9mm 0.6×1.0mm 0.5×0.8mm 2.0×4.5mm
Linearity (*2) ±0.1% F.S. ±0.3% F.S.
Resolution (*3) Fast 4μm 8μm 15μm 45μm 100μm
Other 2μm 5μm 10μm 30μm 75μm
Temp drift ±0.08%F.S. / ?
Response time (*4) Fast 1ms+ selecting sensitivity (averaging : 1) 1.5ms+ selecting sensitivity (averaging : 1)
Standard 8.5ms+ selecting sensitivity (averaging : 16) 13ms+ selecting sensitivity (averaging : 16)
High resolution 32.5ms+ selecting sensitivity (averaging : 64) 49ms+ selecting sensitivity (averaging : 64)
Selecting sensitivity 4ms max.
Indicators Distance indicator bar graph LED
Output indicator ON status : Orange
Protection category IP67
Ambient temp / humidity ?10?+45? / 35?85%RH (No condensation or freezing)
Storage temp / humidity ?20?+60? / 35?95%RH (No condensation or freezing)
Ambient illuminance Sun light : 10,000lx max. Incandescent lamp : 3,000lx max.
Vibration resistance 10 to 55 Hz, Double amplitude 1.5 mm, 2 h for XYZ axis
Shock resistance 50G (500m/s2)
Cable extension Up to 10m using an optional extension cable
Material PBT (Case) PMMA (Front window)
Weight Cable type approx.65g (without cable)
Connector type approx.70g

 

Model 2 Control output + Analog 4-20mA + Analog 0-10V 1 Control output + RS422
Supply voltage 12 - 24VDC ?-5%, +10%? 18 - 24VDC ?-5%, +10%? 12 - 24VDC ?-5%, +10%?
Current consumption max. 55mA (24VDC) max. 85mA (24VDC) max. 55mA (24VDC)
Output Control output 1 NPN / PNP open collector 100mA max. / 30VDC ?residual voltage max. 1.8V? ?
Control output 2 NPN / PNP open collector 100mA max. / 30VDC ?residual voltage max. 1.8V?
Analog output ? 4-20mA 0-10V ?
Interface ? RS422
Cable type Dia : 5mm 5core 2m AWG24 ?PVC? Dia : 5mm 6core 2m AWG24 ?PVC? Dia : 5mm 8core 2m AWG24 ?PVC?
Connector type M12 8pin

*1 Defined with center strength 1/e2?13.5??. There may be leak light other than the specified spot size. The sensor may be affected when there is a highly reflective object around the targets.

*2 Averaging : 64?High resolution?, Object : white ceramic.

*3 Middle of measuring range, Object : white ceramic.

*4 Response time : response time plus selecting sensitivity time.


Model Cable type 2control output
+ Analog 4-20mA
CD33-L30NA / PA CD33-L50NA / PA CD33-L85NA / PA
2control output
+ Analog 0-10V
CD33-L30NV / PV CD33-L50NV / PV CD33-L85NV / PV
1control output
+ RS422
CD33-L30N-422 / P-422 CD33-L50N-422 / P-422 CD33-L85N-422 / P-422
Connector type 2control output
+ Analog 4-20mA
CD33-L30CNA / CPA CD33-L50CNA / CPA CD33-L85CNA / CPA
2control output
+ Analog 0-10V
CD33-L30CNV / CPV CD33-L50CNV / CPV CD33-L85CNV / CPV
1control output
+ RS422
CD33-L30CN-422 / CP-422 CD33-L50CN-422 / CP-422 CD33-L85CN-422 / CP-422
Control output N = NPN open collector, P = PNP open collector
Measurement range 26.3±2mm 47.3±5mm 82.9±10mm
Full scale 4mm 10mm 20mm
Light source Red laser diode, 655nm
Peak power 390μW max.
IEC/JIS Class Class 1
FDA CLASS CLASS ?
Spot size
(approx.volume) (*1)
Near 0.15×0.15mm
Middle 0.1×0.1mm
Far 0.15×0.15mm
Linearity (*2) ±0.2% F.S.
Resolution (*3) 1μm 2.5μm 5μm
Temp drift ±0.08%F.S. / ?
Response time (*4) Fast 1ms+ selecting sensitivity (averaging : 1)
Standard 8.5ms+ selecting sensitivity (averaging : 16)
High resolution 32.5ms+ selecting sensitivity (averaging : 64)
Selecting sensitivity 4ms max.
Indicators Distance indicator bar graph LED
Output indicator ON status : Orange
Protection category IP67
Ambient temp / humidity ?10?+45? / 35?85%RH (without condensing)
Storage temp / humidity ?20?+60? / 35?95%RH (without condensing)
Ambient illuminance Incandescent lamp : 3,000lx max.
Vibration resistance 10 to 55 Hz, Double amplitude 1.5 mm, 2 h for XYZ axis
Shock resistance 50G (500m/s2) XYZ 3times
Cable extension Up to 10m using an optional extension cable
Material PBT (Case) PMMA (Front window)
Weight Cable type approx.65g (without cable)
Connector type approx.70g

DESCARGAS
CONTACTANOS